skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Search for: All records

Creators/Authors contains: "Sameera, Jannatun Noor"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Free, publicly-accessible full text available April 15, 2026
  2. Free, publicly-accessible full text available January 22, 2026
  3. A 28-GHz multibeam joint communication and sensing system called SideSense is presented, in which a line-of-sight (LoS) beam is used to maintain reliable communication, while other sensing beams are used to enhance physiological motion detection. SideSense decodes the motion frequency and shape from the channel state information (CSI) by first tuning the gain ratio and phase differences between the LoS communication beam and non-LoS (NLoS) beam to maximize the sensing signal-to-noise ratio (SSNR) without significantly degrading the communication channel capacity (CCC). Analytical results based on a bistatic model are presented to show a gain ratio of around 1 and a phase difference of 90° or 270°, which are ideal for optimizing both SSNR and CCC. Experiments based on an array of phased array (APA) beamformers and orthogonal frequency-division multiplexing (OFDM) waveforms with phantom and human subjects are presented to validate the performance of SideSense. Results show that SideSense can improve SSNR by 84% while reducing CCC by 35%, an acceptable decrease within the normal operational parameters of a millimeter-wave (mmWave) communication system, which would not trigger a link reestablishment procedure, e.g., communication beam realignment. 
    more » « less
    Free, publicly-accessible full text available January 1, 2026
  4. This paper proposes a spectral binning method for the classification of locomotion and extraneous body motion (EBM) that may occur during Continuous Wave (CW) Doppler radar motion sensing of human subjects. The method analyzes the spectral content of the arctangent demodulated displacement signature, generating an activity classification based on the magnitude of the spectral content for each of several frequency bins. The choice and number of bins used for the overall classification of data were determined by analyzing experimental data. The method successfully classified sedentary, EBM, and locomotion states for 5 subjects. The method can be used both for determining the presence and type of activity, and for recognizing when data segments are not suitable for monitoring sedentary vital signs. 
    more » « less
  5. The significant impact of environmental noise on cardiovascular health is becoming more widely recognized. However, detailed studies related to environmental noise and human physiology are very limited. This study provides a detailed evaluation of heart rate and respiratory responses to different noise levels in a controlled experimental environment using Doppler radar. The findings indicate that while respiratory rates show notable variations, heart rates remain largely unchanged with alterations in noise levels. This non-invasive approach to assessing the effects of environmental noise using Doppler radar could help improve indoor environmental quality by adapting conditions to enhance acoustic comfort and reduce stress for occupants. 
    more » « less
  6. A Doppler radar measurement of respiration is a well-known technique for assessment of respiratory rates and patterns. Torso respiratory motion is a result of thoracic and abdominal motion during normal breathing. These two contributions produce breathing patterns that are important to understand for assessing respiratory health and sleep disorders. Doppler radar systems often use an antenna beam that illuminates the whole torso, effectively combining the contributions from the two regions. This paper presents theory, simulation, and measurement results that analyze and validate thorax and abdomen motion contributions in Doppler radar respiratory measurement. 
    more » « less
  7. A static algorithm-based method is described here to differentiate between recoverable sedentary respiratory rate data extraneous motion segments measured using Doppler radar. Extraneous motion such as locomotion and fidgeting can cause drastic changes in dc offset and SNR of the received signal. Such extraneous data may not be excluded and can lead to an erroneous assessment of the respiration rate. In some cases, however, moderate distinct extraneous motion does not completely occlude the measurement of respiratory torso motion, allowing for respiration rate recovery. This work focuses on the accurate classification of data which is suitable for respiration rate analysis in the presence of locomotion and small extraneous movements. The proposed algorithm has been demonstrated to be accurate for classifying data with recoverable respiratory rates for 2 subjects and 3 types of fidgets with 99.4% accuracy on average. 
    more » « less
  8. Heart rate variability (HRV) analysis using Doppler radar (DR) is a promising method for noninvasive health and stress assessment. However, the respiration signal harmonic content typically limits HRV parameter estimation accuracy. While several harmonic reduction techniques have been used to improve the average HR estimation accuracy, achieving high beat-to-beat interval (BBI) accuracy is still challenging. This article demonstrates that arctangent demodulation (AD) with wavelet-based signal processing enhanced with template matching is effective to estimate HRV parameters with accuracy on the order of 10 ms with 2.4 GHz DR. Moreover, it was theoretically and experimentally demonstrated that the cases where AD provides limited improvement due to phase delay between thorax and abdomen motion are easily identifiable, and can be alternatively processed using a single-channel data. 
    more » « less
  9. This study examines the use of a Doppler radar occupancy sensor to assess thermal adaptation. Current heating, ventilation, and air-conditioning (HVAC) systems are important for the productivity of employees and the healing of patients; however, their control systems are typically limited to a narrow temperature range, which is usually not comfortable for most occupants. Occupant vital signs can be used to assess thermal comfort, due to the role cardiovascular regulation plays in heat dissipation. This research aims to correlate physiological and thermal adaptation with the goal of optimizing HVAC system operation. A Doppler radar occupancy sensor was used to measure the physiological parameters of ten human subjects under two temperature conditions, and thermal comfort surveys were used to record thermal sensation. The results demonstrate that the Doppler radar occupancy sensor could not only detect heart rate changes due to a significant environmental temperature difference but also detect subtle changes in heart rate during thermal adaptation that were not captured by the surveys. 
    more » « less